1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20200312, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430488

RESUMO

Abstract Background Dental anesthetic management in implantable cardioverter defibrillator (ICD) recipients with cardiac channelopathies (CCh) can be challenging due to the potential risk of life-threatening arrhythmias and appropriate ICD therapies during procedural time. Objectives The present study assessed the hypothesis that the use of local dental anesthesia with 2% lidocaine with 1:100,000 epinephrine or without a vasoconstrictor can be safe in selected ICD and CCh patients, not resulting in life-threatening events (LTE). Methods Restorative dental treatment under local dental anesthesia was made in two sessions, with a wash-out period of 7 days (cross-over trial), conducting with a 28h - Holter monitoring, and 12-lead electrocardiography, digital sphygmomanometry, and anxiety scale assessments in 3 time periods. Statistical analysis carried out the paired Student's t test and the Wilcoxon signed-rank test. In all cases, a significance level of 5% was adopted. All patients were in stable condition with no recent events before dental care. Results Twenty-four consecutive procedures were performed in 12 patients (9 women, 3 men) with CCh and ICD: 7 (58.3%) had long QT syndrome (LQTS), 4 (33.3%) Brugada syndrome (BrS), and 1 (8.3%) Catecholaminergic polymorphic ventricular tachycardia (CPVT). Holter analysis showed no increased heart rate (HR) or sustained arrhythmias. Blood pressure (BP), electrocardiographic changes and anxiety measurement showed no statistically significant differences. No LTE occurred during dental treatment, regardless of the type of anesthesia. Conclusion Lidocaine administration, with or without epinephrine, can be safely used in selected CCh-ICD patients without LTE. These preliminary findings need to be confirmed in a larger population with ICD and CCh.

2.
Arq. bras. cardiol ; 120(8): e20220833, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1505742

RESUMO

Resumo Fundamento: A morte súbita cardíaca (MSC), decorrente de arritmias ventriculares, é a principal complicação da cardiomiopatia hipertrófica (CMH). A microalternância da onda T (MAOT) está associada à ocorrência de arritmias ventriculares em diversas cardiopatias, mas seu papel na CMH permanece incerto. Objetivo: Avaliar associação da MAOT com a ocorrência de MSC ou arritmias ventriculares malignas em pacientes com CMH. Método: Pacientes com diagnóstico de CMH e classe funcional I-II (NYHA) foram selecionados de forma consecutiva. No início do seguimento os participantes realizaram a avaliação da MAOT pela metodologia da média móvel modificada no teste de esforço. Os resultados foram classificados em alterado ou normal. O desfecho foi composto por MSC, fibrilação ventricular, taquicardia ventricular sustentada (TVS) e terapia apropriada do cardioversor desfibrilador implantável (CDI). O nível de significância estatística foi de 5%. Resultados: Um total de 132 pacientes (idade média de 39,5±12,6 anos) foram incluídos, com tempo de seguimento médio de 9,5 anos. A MAOT foi alterada em 74 (56%) participantes e normal em 58 (44%). Durante o seguimento, nove (6,8%) desfechos ocorreram, com prevalência de 1,0%/ano, sendo seis casos de MSC, dois choques apropriados do CDI e um episódio de TVS. MAOT alterada foi associada à taquicardia ventricular não sustentada no Holter (p=0,016), espessura septal≥30 mm (p<0,001) e resposta inadequada da pressão arterial ao esforço (p=0,046). Cinco pacientes (7%) e quatro pacientes (7%) com MAOT alterada e normal, respectivamente, apresentaram desfecho primário [OR=0,85(IC95%: 0,21-3,35, p=0,83)]. Curvas de eventos de Kaplan-Meir não apresentaram diferenças entre MAOT normal e alterada. Conclusão: A MAOT alterada não foi associada à ocorrência de MSC ou arritmias ventriculares potencialmente fatais em pacientes com CMH, e a baixa taxa desses eventos em um seguimento em longo prazo sugere o bom prognóstico dessa cardiopatia.


Abstract Background: Sudden cardiac death (SCD) resulting from ventricular arrhythmia is the main complication of hypertrophic cardiomyopathy (HCM). Microvolt T-wave alternans (MTWA) is associated with the occurrence of ventricular arrhythmias in several heart diseases, but its role in HCM remains uncertain. Objective: To evaluate the association of MTWA with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients in a long-term follow-up. Methods: Patients diagnosed with HCM and NYHA functional class I-II were consecutively selected. At the beginning of the follow-up, the participants performed the MTWA evaluation using the modified moving average during the stress test. The results were classified as altered or normal. The composite endpoint of SCD, ventricular fibrillation, sustained ventricular tachycardia (SVT) or appropriate implantable cardiac defibrillation (ICD) therapy was assessed. The level of significance was set at 5%. Results: A total of 132 patients (mean age of 39.5 ± 12.6 years) were recruited and followed for a mean of 9.5 years. The MTWA test was altered in 74 (56%) participants and normal in 58 (44%). Nine events (6.8%) occurred during the follow-up, with a prevalence of 1.0%/year - six SCDs, two appropriate ICD shocks and one episode of (SVT). Altered MTWA was associated with non-sustained ventricular tachycardia on Holter (p = 0.016), septal thickness ≥30 mm (p < 0.001) and inadequate blood pressure response to effort (p = 0.046). Five patients with altered MTWA (7%) and four patients with normal MTWA (7%) had the primary outcome [OR = 0.85 (95% CI: 0.21 - 3.35, p=0.83)]. Kaplan-Meir event curves showed no differences between normal and altered MTWA. Conclusion: Altered MTWA was not associated with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients, and the low rate of these events during long-term follow-up suggests the good prognosis of this heart disease.

6.
Arq. bras. cardiol ; 119(4): 587-592, Oct. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1403352

RESUMO

Resumo Fundamento O período neonatal é marcado por muitas alterações importantes no sistema cardiovascular, principalmente na primeira semana de vida. Diferentemente da população adulta, estudos sobre dados de eletrocardiograma (ECG) no período neonatal são escassos. Este é o primeiro estudo a descrever alterações eletrocardiográficas em uma coorte de recém-nascidos com ecocardiogramas normais. Objetivos Analisar padrões eletrocardiográficos de uma população de recém-nascidos a termo, sem anomalias morfológicas ou funcionais cardíacas, e comparar os resultados com a literatura. Métodos Neste estudo observacional, ecocardiogramas e resultados de ECG de 94 neonatos divididos em três grupos etários (até 24 horas, entre 25 e 72 horas, e entre 73 e 168 horas de vida) foram avaliados e comparados com aqueles descritos por Davignon et al. Um valor de p < 0,05 foi considerado estatisticamente significativo. Resultados Diferenças significativas na direção da onda T foram detectadas nas derivações V1 (p= 0,04), V2 (p= 0,02), V3 (p= 0,008) e V4 (p= 0,005). Houve diferenças entre nossos resultados e a literatura atual na maioria dos parâmetros. Conclusão Recém-nascidos a termo com menos de 24 horas de vida apresentaram significativamente mais ondas T positivas que aqueles com mais horas de vida. Encontramos muitas diferenças nos parâmetros de ECG em comparação aos descritos por Davignon et al., particularmente nas amplitudes de P, Q, R, S, duração do QRS, R/S e R+S. Esses achados indicam a necessidade de mais estudos para uma interpretação definitiva do ECG em recém-nascidos.


Abstract Background The neonatal period is marked by major changes in the cardiovascular system, especially in the first week of life. Unlike the adult population, studies on electrocardiogram (ECG) data in the neonatal period are scarce. This is the first study to describe electrocardiographic changes in a cohort of newborns with normal echocardiograms. Objectives To analyze the electrocardiographic patterns of a population of full-term NB, without any cardiac morphological or functional anomalies, and compare the results with the literature. Methods In this observational study, echocardiograms and ECG results from 94 newborns divided in three age groups (up to 24 hours, between 25 and 72 hours, and between 73 and 168 hours of life) were evaluated and compared with those reported by Davignon et al. A p-value <0.05 was considered statistically significant. Results There were significant differences in T-wave direction in leads V1 (p= 0.04), V2 (p= 0.02), V3 (p= 0.008) and V4 (p= 0.005) between the three age groups. There were differences between our findings and the current literature in most of the parameters. Conclusion Term newborns within 24 hours of life showed significantly more positive T waves than older ones. Many differences from the Davignon's ECG parameters were found, particularly in the P, Q, R, S amplitudes, QRS duration, R/S and R+S. These findings indicate that more studies are needed for a definitive interpretation of the ECG in newborns.

8.
Arq. bras. cardiol ; 113(1): 87-99, July 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1011237

RESUMO

Abstract The electrocardiogram (ECG) has been reinvigorated by the identification of electrical alterations that were not definitely clarified before. In this context, and mainly regarding the definition of arrhythmogenic substrates, the association of the ECG with the vectorcardiogram (VCG) has gathered much more information about the cardiac electrical phenomena, thus allowing us to differentiate potentially fatal cases from benign ones. Obtaining a VCG concomitantly with the performance of an ECG has led to a significant gain in the definition of extremely sophisticated pathologies, which function suffer some type of structural or dynamic alterations, involving either the reduction or enhancement of ionic channels and currents. The classic aspects of the ECG/VCG association in the differential diagnosis of myocardial infarctions, conduction disorders, atrial and ventricular hypertrophies, and the correlations between these electrical disorders are still valid and assertive. The association of these pathologies is further clarified when they are seen through the ECG/VCG dyad. The three-dimensional spatial orientation of both the atrial and the ventricular activity provides a far more complete observation tool than the ECG linear form. The modern analysis of the ECG and its respective VCG, simultaneously obtained by the recent technique called electro-vectorcardiogram (ECG/VCG), brought a significant gain for the differential diagnosis of some pathologies. Therefore, we illustrate how this type of analysis can elucidate some of the most important diagnoses found in our daily clinical practice as cardiologists.


Resumo O eletrocardiograma (ECG) foi revigorado com o reconhecimento de alterações elétricas que ainda não haviam sido observadas de maneira definitiva. Nesse contexto, principalmente na definição dos substratos arritmogênicos, a associação do ECG com o vetorcardiograma (VCG) propiciou mais informações sobre os fenômenos elétricos cardíacos, possibilitando distinguir os casos potencialmente fatais dos benignos. A obtenção de um VCG ao mesmo tempo da realização do ECG trouxe um ganho muito importante para definir patologias extremamente sofisticadas, com alterações estruturais ou dinâmicas que envolvem canais e correntes iônicas, cujas funções são diminuídas ou exageradas em razão de mutações genéticas. Os aspectos clássicos da relação ECG/VCG no diagnóstico diferencial das áreas inativas, dos distúrbios de condução, das sobrecargas atriais e ventriculares e das associações entre esses distúrbios elétricos continuam vigentes e assertivos, e ficam mais claros quando vistos pelo binômio ECG/VCG. Além disso, a orientação espacial tridimensional das atividades atrial e ventricular cria uma ferramenta de observação muito mais completa do que o modo linear do ECG. A análise moderna do ECG e do respectivo VCG, obtidos simultaneamente pela técnica recente chamada de eletrovetorcardiograma (ECG/VCG), trouxe um ganho importante no diagnóstico diferencial de algumas patologias. Desse modo, são abordadas aqui as principais utilidades dessa análise na elucidação de diagnósticos importantes da atividade diária na clínica cardiológica.


Assuntos
Humanos , Vetorcardiografia , Cardiopatias/diagnóstico , Padrões de Prática Médica , Diagnóstico Diferencial , Cardiopatias/fisiopatologia
9.
Clinics ; 72(6): 343-350, June 2017. tab
Artigo em Inglês | LILACS | ID: biblio-840087

RESUMO

OBJECTIVES: In athletes, isolated electrocardiogram high voltage criteria are widely used to evaluate left ventricular hypertrophy, but positive findings are thought to represent normal electrocardiogram alterations. However, which electrocardiogram criterion can best detect left ventricular hypertrophy in athletes of various sport modalities remains unknown. METHODS: Five electrocardiogram criteria used to detect left ventricular hypertrophy were tested in 180 male athletes grouped according to their sport modality: 67% low-static and high-dynamic components and 33% high-static and high-dynamic components of exercise. The following echocardiogram parameters are the gold standard for diagnosing left ventricular hypertrophy: left ventricular mass index ≥134 g.m-2, relative wall thickness ≥0.42 mm, left ventricular diastolic diameter index ≥32 mm.m-2, septum wall thickness ≥13 mm, and posterior wall thickness ≥13 mm. Results for the various criteria were compared using the kappa coefficient. Significance was established at p<0.05. RESULTS: Fifty athletes (28%) presented with left ventricular hypertrophy according to electrocardiogram findings, with the following sensitivities and specificities, respectively: 38-53% and 79-83% (Perugia), 22-40% and 89-91% (Cornell), 24-29% and 90% (Romhilt-Estes), 68-87% and 20-23% (Sokolow-Lyon), and 0% and 99% (Gubner). The Perugia and Cornell criteria had higher negative predictive values for the low-static and high-dynamic subgroup. Kappa coefficients were higher for Romhilt-Estes, Cornell and Perugia criteria than for Sokolow-Lyon and Gubner criteria. CONCLUSION: All five evaluated criteria are inadequate for detecting left ventricular hypertrophy, but the Perugia, Cornell and Romhilt-Estes criteria are useful for excluding its presence. The Perugia and Cornell criteria were more effective at excluding left ventricular hypertrophy in athletes involved in a sport modality with low-static and high-dynamic component predominance.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Atletas , Hipertrofia Ventricular Esquerda/diagnóstico , Esportes/fisiologia , Eletrocardiografia , Sensibilidade e Especificidade , Esportes/estatística & dados numéricos
10.
Arq. bras. cardiol ; 107(5): 392-402, Nov. 2016.
Artigo em Inglês | LILACS | ID: biblio-827866

RESUMO

Abstract The third version of the guidelines covers recently described topics, such as ion channel diseases, acute ischemic changes, the electrocardiogram in athletes, and analysis of ventricular repolarization. It sought to revise the criteria for overloads, conduction disorders, and analysis of data for internet transmission.


Resumo A terceira versão das diretrizes aborda tópicos recentemente descritos, como as doenças dos canais iônicos, alterações isquêmicas agudas, o eletrocardiograma dos atletas e análise da repolarização ventricular. Ela buscou rever critérios de sobrecargas, distúrbios de condução e análise de dados transmitidos via internet.


Assuntos
Humanos , Doenças Cardiovasculares/diagnóstico , Eletrocardiografia/normas , Arritmias Cardíacas/diagnóstico , Sociedades Médicas , Esportes , Brasil , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/genética , Função Ventricular/fisiologia , Diagnóstico Diferencial , Atletas , Infarto do Miocárdio/diagnóstico
12.
In. Pastore, Alberto Carlos; Samesima, Nelson; Tobias, Nancy Maria Martins de Oliveira; Pereira Filho, Horacio Gomes. Eletrocardiografia atual: curso do serviço de eletrocardiografia do InCor. São Paulo, Atheneu, 3º; 2016. p.265-278.
Monografia em Português | LILACS | ID: biblio-833693
13.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.185-223.
Monografia em Português | LILACS | ID: biblio-971537
14.
Arq. bras. cardiol ; 105(1): 53-64, July 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-755002

RESUMO

Background:

Information about post-acute coronary syndrome (ACS) survival have been mostly short-term findings or based on specialized, cardiology referral centers.

Objectives:

To describe one-year case-fatality rates in the Strategy of Registry of Acute Coronary Syndrome (ERICO) cohort, and to study baseline characteristics as predictors.

Methods:

We analyzed data from 964 ERICO participants enrolled from February 2009 to December 2012. We assessed vital status by telephone contact and official death certificate searches. The cause of death was determined according to the official death certificates. We used log-rank tests to compare the probabilities of survival across subgroups. We built crude and adjusted (for age, sex and ACS subtype) Cox regression models to study if the ACS subtype or baseline characteristics were independent predictors of all-cause or cardiovascular mortality.

Results:

We identified 110 deaths in the cohort (case-fatality rate, 12.0%). Age [Hazard ratio (HR) = 2.04 per 10 year increase; 95% confidence interval (95%CI) = 1.75–2.38], non-ST elevation myocardial infarction (HR = 3.82 ; 95%CI = 2.21–6.60) or ST elevation myocardial infarction (HR = 2.59; 95%CI = 1.38–4.89) diagnoses, and diabetes (HR = 1.78; 95%CI = 1.20‑2.63) were significant risk factors for all-cause mortality in the adjusted models. We found similar results for cardiovascular mortality. A previous coronary artery disease diagnosis was also an independent predictor of all-cause mortality (HR = 1.61; 95%CI = 1.04–2.50), but not for cardiovascular mortality.

Conclusion:

We found an overall one-year mortality rate of 12.0% in a sample of post-ACS patients in a community, non-specialized hospital in São Paulo, Brazil. Age, ACS subtype, and diabetes were independent predictors ...


Fundamento:

Dados sobre sobrevida após uma síndrome coronariana aguda (SCA) são geralmente de curto prazo ou baseados em centros cardiológicos.

Objetivo:

Descrever a frequência de ocorrência de óbito em um ano no Estudo de Registro de Insuficiência Coronariana (ERICO), e seus preditores.

Métodos:

Foram analisados 964 participantes ERICO incluídos de fevereiro/2009 a dezembro/2012. O estado vital dos participantes foi obtido por telefone e fontes oficiais de óbito. A causa de morte foi determinada pelos certificados de óbito. Foi utilizado o teste log-rank para comparar probabilidades de sobrevivência. Construímos modelos de regressão de Cox, brutos e ajustados (para idade, sexo e subtipo de SCA), para estudar se o subtipo de SCA ou características de entrada no estudo foram preditores independentes de mortalidade.

Resultados:

Identificamos 110 óbitos (frequência de ocorrência de óbito, 12,0%). A idade (risco relativo [RR] em 10 anos = 2,04; intervalo de confiança de 95% [IC95%]=1,75-2,38), infarto do miocárdio sem elevação do segmento ST (RR = 3,82; IC95% = 2,21-6,60) ou infarto do miocárdio com elevação do segmento ST (RR = 2,59; IC95% = 1,38‑4,89) e diabetes (RR = 1,78; IC95% = 1,20-2,63) foram fatores de risco significativos para mortalidade geral em modelos ajustados. Encontramos resultados semelhantes para mortalidade cardiovascular. Diagnóstico prévio de doença arterial coronariana também foi um preditor independente de mortalidade geral (RR = 1,61; IC95% = 1,04-2,50), mas não de mortalidade cardiovascular.

Conclusão:

Encontramos uma frequência de ocorrência de óbito em um ano de 12,0% nesta amostra de pacientes pós-SCA de um hospital comunitário em São Paulo. Idade, subtipo de SCA e diabetes foram preditores independentes de pior sobrevida em um ano.

.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda/mortalidade , Fatores Etários , Brasil/epidemiologia , Complicações do Diabetes/mortalidade , Métodos Epidemiológicos , Hospitalização , Hipertensão/complicações , Prognóstico , Fatores de Risco , Sistema de Registros/estatística & dados numéricos , Fatores Sexuais , Fatores de Tempo
15.
Clinics ; 68(7): 986-991, jul. 2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-680714

RESUMO

OBJECTIVES: Few studies have evaluated cardiac electrical activation dynamics after cardiac resynchronization therapy. Although this procedure reduces morbidity and mortality in heart failure patients, many approaches attempting to identify the responders have shown that 30% of patients do not attain clinical or functional improvement. This study sought to quantify and characterize the effect of resynchronization therapy on the ventricular electrical activation of patients using body surface potential mapping, a noninvasive tool. METHODS: This retrospective study included 91 resynchronization patients with a mean age of 61 years, left ventricle ejection fraction of 28%, mean QRS duration of 182 ms, and functional class III/IV (78%/22%); the patients underwent 87-lead body surface mapping with the resynchronization device on and off. Thirty-six patients were excluded. Body surface isochronal maps produced 87 maximal/mean global ventricular activation times with three regions identified. The regional activation times for right and left ventricles and their inter-regional right-to-left ventricle gradients were calculated from these results and analyzed. The Mann-Whitney U-test and Kruskall-Wallis test were used for comparisons, with the level of significance set at p≤0.05. RESULTS: During intrinsic rhythms, regional ventricular activation times were significantly different (54.5 ms vs. 95.9 ms in the right and left ventricle regions, respectively). Regarding cardiac resynchronization, the maximal global value was significantly reduced (138 ms to 131 ms), and a downward variation of 19.4% in regional-left and an upward variation of 44.8% in regional-right ventricular activation times resulted in a significantly reduced inter-regional gradient (43.8 ms to 17 ms). CONCLUSIONS: Body surface potential mapping in resynchronization patients yielded electrical ventricular ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mapeamento Potencial de Superfície Corporal/métodos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Bloqueio de Ramo/fisiopatologia , Terapia por Estimulação Elétrica , Insuficiência Cardíaca/fisiopatologia , Valores de Referência , Estudos Retrospectivos , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia
16.
Clinics ; 68(3): 431-434, 2013. tab
Artigo em Inglês | LILACS | ID: lil-671441

RESUMO

OBJECTIVES: To describe the ERICO study (Strategy of Registry of Acute Coronary Syndrome), a prospective cohort to investigate the epidemiology of acute coronary syndrome. METHODS: The ERICO study, which is being performed at a secondary general hospital in São Paulo, Brazil, is enrolling consecutive acute coronary syndrome patients who are 35 years old or older. The sociodemographic information, medical assessments, treatment data and blood samples are collected at admission. After 30 days, the medical history is updated, and additional blood and urinary samples are collected. In addition, a retinography, carotid intima-media thickness, heart rate variability and pulse-wave velocity are performed. Questionnaires about food frequency, physical activity, sleep apnea and depression are also applied. At six months and annually after an acute event, information is collected by telephone. RESULTS: From February 2009 to September 2011, 738 patients with a diagnosis of an acute coronary syndrome were enrolled. Of these, 208 (28.2%) had ST-elevation myocardial infarction (STEMI), 288 (39.0%) had non-ST-elevation myocardial infarction (NSTEMI) and 242 (32.8%) had unstable angina (UA). The mean age was 62.7 years, 58.5% were men and 77.4% had 8 years or less of education. The most common cardiovascular risk factors were hypertension (76%) and sedentarism (73.4%). Only 29.2% had a prior history of coronary heart disease. Compared with the ST-elevation myocardial infarction subgroup, the unstable angina and non-ST-elevation myocardial infarction patients had higher frequencies of hypertension, diabetes, prior coronary heart disease (p<0.001) and dyslipidemia (p = 0.03). Smoking was more frequent in the ST-elevation myocardial infarction patients (p = 0.006). CONCLUSIONS: Compared with other hospital registries, our findings revealed a higher burden of CV risk factors and less frequent prior CHD history.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome Coronariana Aguda/epidemiologia , Doença das Coronárias/epidemiologia , Sistema de Registros/normas , Brasil/epidemiologia , Métodos Epidemiológicos , Reprodutibilidade dos Testes , Fatores de Risco , Fatores de Tempo
17.
Arq. bras. cardiol ; 96(3): e53-e61, mar. 2011. ilus, graf
Artigo em Português | LILACS | ID: lil-581468

RESUMO

Reconhecer com precisão indivíduos com maior risco imediato de morte súbita cardíaca (MSC) ainda é uma questão em aberto. A natureza fortuita dos eventos cardiovasculares agudos não parece se adequar ao conhecido modelo de indução de taquicardia/fibrilação ventricular por um gatilho em sincronia a um substrato arritmogênico estático. Quanto ao mecanismo da MSC, uma instabilidade elétrica dinâmica explicaria melhor a raridade da associação simultânea de um gatilho certo a um substrato cardíaco apropriado. Diversos estudos tentaram medir essa instabilidade elétrica cardíaca (ou um equivalente válido) em uma sequência de batimentos cardíacos no ECG. Dentre os mecanismos possíveis podemos citar o prolongamento do QT, dispersão do QT, potenciais tardios, alternância de onda T ou T-wave alternans (TWA), e turbulência da frequência cardíaca. Este artigo se atém em particular ao papel da TWA no panorama atual da estratificação de risco cardíaco. Os achados sobre TWA ainda são heterogêneos, variando de um desempenho prognóstico muito bom até um quase nulo, dependendo da população clínica observada e protocolo clínico usado. Para preencher as atuais lacunas no conhecimento sobre TWA, profissionais médicos e pesquisadores devem explorar melhor as características técnicas das diversas tecnologias disponíveis para a avaliação de TWA e atentar ao fato de que os valores de TWA respondem a diversos outros fatores, além de medicamentos. Informações sobre mecanismos celulares e subcelulares da TWA estão fora do escopo deste artigo, mas são referenciados alguns dos principais trabalhos sobre este tópico, com o intuito de auxiliar no entendimento dos conceitos e fatos cobertos neste artigo.


Accurate recognition of individuals at higher immediate risk of sudden cardiac death (SCD) is still an open question. The fortuitous nature of acute cardiovascular events just does not seem to fit the well-known model of ventricular tachycardia/fibrillation induction in a static arrhythmogenic substrate by a synchronous trigger. On the mechanism of SCD, a dynamical electrical instability would better explain the rarity of the simultaneous association of a correct trigger and an appropriate cardiac substrate. Several studies have been conducted trying to measure this cardiac electrical instability (or any valid surrogate) in an ECG beat stream. Among the current possible candidates we can number QT prolongation, QT dispersion, late potentials, T-wave alternans (TWA), and heart rate turbulence. This article reviews the particular role of TWA in the current cardiac risk stratification scenario. TWA findings are still heterogeneous, ranging from very good to nearly null prognostic performance depending on the clinical population observed and clinical protocol in use. To fill the current gaps in the TWA base of knowledge, practitioners, and researchers should better explore the technical features of the several technologies available for TWA evaluation and pay greater attention to the fact that TWA values are responsive to several factors other than medications. Information about the cellular and subcellular mechanisms of TWA is outside the scope of this article, but the reader is referred to some of the good papers available on this topic whenever this extra information could help the understanding of the concepts and facts covered herein.


Reconocer con precisión individuos con mayor riesgo inmediato de muerte súbita cardíaca (MSC) aun es una cuestión en abierto. La naturaleza fortuita de los eventos cardiovasculares agudos no parece adecuarse al conocido modelo de inducción de taquicardia/fibrilación ventricular por un gatillo en sincronía con un substrato arritmogénico estático. En cuanto al mecanismo de la MSC, una inestabilidad eléctrica dinámica explicaría mejor la rareza de la asociación simultánea de un gatillo correcto a un substrato cardíaco apropiado. Diversos estudios trataron de medir esa inestabilidad eléctrica cardíaca (o un equivalente válido) en una secuencia de latidos cardíacos en el ECG. Entre los mecanismos posibles podemos citar la prolongación del QT, dispersión del QT, potenciales tardíos, alternancia de onda T o T-wave alternans (TWA), y turbulencia de la frecuencia cardíaca. Este artículo se atiene en particular al papel de la TWA en el panorama actual de la estratificación de riesgo cardíaco. Los hallazgos sobre TWA aun son heterogéneos, variando de un desempeño pronóstico muy bueno hasta uno casi nulo, dependiendo de la población clínica observada y protocolo clínico usado. Para llenar las actuales lagunas en el conocimiento sobre TWA, profesionales médicos e investigadores deben explotar mejor las características técnicas de las diversas tecnologías disponibles para la evaluación de TWA y estar atento al hecho de que los valores de TWA responden a otros diversos factores, además de medicamentos. Informaciones sobre mecanismos celulares y subcelulares de la TWA están fuera del objetivo de este artículo, pero son referenciados algunos de los principales trabajos sobre este tópico, con el propósito de auxiliar en la comprensión de los conceptos y hechos cubiertos en este artículo.


Assuntos
Humanos , Eletrocardiografia/métodos , Cardiopatias/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Cardiopatias/fisiopatologia , Frequência Cardíaca/fisiologia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco
18.
São Paulo; s.n; 2011. [93] p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-609347

RESUMO

INTRODUÇÃO: Os benefícios na morbi-mortalidade obtidos pela terapia de ressincronização cardíaca (TRC) em pacientes com insuficiência cardíaca estão bem estabelecidos. Métodos invasivos e não invasivos têm sido utilizados para identificar aqueles que realmente se beneficiarão da TRC, mas 30% destes pacientes não apresentam melhora clínica/funcional. Poucos estudos avaliaram o comportamento elétrico dos pacientes submetidos à TRC. OBJETIVO: Utilizamos um método não invasivo, o mapeamento eletrocardiográfico de superfície (MES) para caracterizar o padrão da ativação elétrica ventricular em pacientes após a TRC. MÉTODOS: Estudamos 91 pacientes submetidos à TRC, com insuficiência cardíaca e bloqueio de ramo esquerdo (BRE), sendo 36 excluídos devido a FA (20), BRD (3), cardiopatias hipertrófica (3) e congênita (1) ou dependentes de marcapasso antes da TRC (9). Idade média:61±10 anos, FEVE:0,28±0,9, QRS:182±24ms, classe funcional NYHA: III(78%) e IV(22%). Com o ressincronizador ligado e desligado, todos realizaram o MES, o qual fornece 87 derivações simultâneas (58 anteriores e 29 posteriores). Os mapas isócronos obtidos pelo MES forneceram os tempos de ativação ventricular (TAV) global máximo e médio nas 87 derivações. Os TAVs obtidos foram regionalizados, sendo calculados os valores médios nas áreas do VD, do septo e do VE. Analisamos a diferença do TAV entre o VD e o VE, entre o septo e o VD e entre o septo e o VE, definidos como TAV Inter-Regional. Utilizados os testes de Mann-Whitney, Kruskall-Wallis, Fisher. Nível de significância: P0.05. RESULTADOS: O MES durante ritmo sinusal e BRE mostrou que os pacientes apresentavam prolongado TAV Global máximo e médio (138ms e 64,8ms, respectivamente) com significativa diferença Regional (54,5 x 56,4 x 95,9ms; p<0,0001; VD, septo e VE, respectivamente). A TRC reduziu o TAV Global máximo (138ms x 131ms; p=0,007) e o TAV Regional do VE (95,9 x 77,3ms; p=0,001). Houve aumento do TAV Regional do VD...


INTRODUCTION: The benefits of lower morbidity and mortality obtained with cardiac resynchronization therapy (CRT) in patients with heart failure are already well established. Invasive and noninvasive methods have been used to identify those who will really benefit from CRT, however 30% of these patients do not improve clinically/functionally. Few studies evaluated the cardiac electrical development of patients undergoing CRT. OBJECTIVE: To obtain through the body surface potential mapping (BSPM), a noninvasive approach, characterization of the ventricular electrical activation development in patients after CRT. METHODS: We studied 91 patients with heart failure and left bundle-branch block (LBBB) who underwent CRT, 36 of whom were excluded for AF (20), RBBB (3), hypertrophic (3) or congenital (1) cardiomyopathy, or depended upon a pacemaker before CRT (9). Mean age was 61±10 years, LVEF 0.28±0.9, QRSd 182±24ms, NYHA functional class III(78%) and IV(22%). All underwent BSPM examination of 87 simultaneous leads (58 on the anterior chest, 29 on the back) with the resynchronization device on, then in intrinsic rhythm and LBBB (device off). The BSPM isochronal maps provided maximal and mean global ventricular activation times (VAT) for all the 87 leads. From VATs thus obtained, separate mean values for the RV, septum and LV areas were then calculated. VAT differences between RV-LV, septum-RV and septum-LV, were analyzed and denominated inter-regional VATs. Mann-Whitney, Kruskall-Wallis and Fisher statistics were used, with P.05 established as the significance level. RESULTS: During sinus rhythm/LBBB the BSPM showed patients evidencing prolonged maximal and mean global VATs (138ms and 64.8ms, respectively), with significant regional differences (54.5 vs 56.4 vs 95.9ms; RV, septum and LV, respectively; p<0.0001). CRT reduced the maximal global VAT (138ms vs 131ms; p=0.007) and the LV regional VAT (95.9 vs 77.3ms; p=0.001). The RV regional VAT increased...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Mapeamento Potencial de Superfície Corporal , Terapia por Estimulação Elétrica , Insuficiência Cardíaca
19.
Arq. bras. cardiol ; 88(3): 251-257, mar. 2007. ilus, graf
Artigo em Português | LILACS | ID: lil-451724

RESUMO

OBJETIVOS: Avaliar a ativação elétrica cardíaca usando Mapeamento Eletrocardiográfico de Superfície (MES), em pacientes com ICC e bloqueio de ramo esquerdo [BRE] submetidos a terapia de ressincronização cardíaca (CRT) com implante de marca-passo átrio-biventricular (MP-BIV). MÉTODOS: Foram analisados os tempos médios de ativação elétrica cardíaca no ventrículo direito (tempo médio de ativação do VD [mVD]), área ântero-septal (mAS), e ventrículo esquerdo (mVE), de 28 pacientes (idade média 61,2±9,5 anos, ICC classe III-IV NYHA, fração de ejeção <40 por cento, BRE com QRS médio 181,2±19,4ms, SAQRS= -8,5°±68,6°), mostrados nos mapas de linhas isócronas do MES, antes e após implante de marca-passo átrio-biventricular, e comparados a valores obtidos em um grupo controle composto de indivíduos normais [GNL], em três situações: (1) BRE nativo, (2) estimulação do VD; e (3) estimulação átrio-biventricular. RESULTADOS: situação (1): mVD e mAS foram semelhantes (41,0±11,8ms x 43,6±13,4ms), com mVE tardio (81,0±12,5ms, p<0,01) perdendo o sincronismo com o VD e a área ântero-septal; situação (2): mVD foi maior que no GNL (86,8±22,9ms, p<0,001), com maior diferença entre mAS e mVE (63,4±20,7ms x 102,7±20,3ms; p<0,001); situação (3): mVE e mVD foram semelhantes (72,0±32,0ms x 71,6±32,3ms), mVD foi maior que no GNL e BRE nativo (71,6±32,3ms x 35,1±10,9ms e 41,0±11,8ms; p<0,001), mAS se aproximou do GNL e BRE nativo (51,3±32,8ms x 50,1±11,4ms e 43,6±13,4ms). CONCLUSÃO: Pelo mapeamento eletrocardiográfico de superfície, tempos de ativação semelhantes no VD e VE e próximos daqueles da região ântero-septal indicam padrões de ativação ventricular sincronizada em portadores de ICC e BRE durante estimulação átrio-biventricular.


OBJECTIVES: To assess cardiac electrical activation by using body surface potential mapping (BSPM), in patients with congestive heart failure (CHF) and left bundle branch block (LBBB) undergoing cardiac resynchronization therapy (CRT) with biventricular pacemaker (BIV-PM) implantation. METHODS: Mean cardiac electrical activation times were analyzed in the right ventricle (RV) (mean RV activation time = mRV), anteroseptal area (mAS), and left ventricle (mLV) of 28 patients (mean age 61.2 ± 9.5 years; NYHA class III-IV CHF; ejection fraction <40 percent; LBBB of mean QRS 181.2±19.4ms, SAQRS -8.5°±68.6°), as shown in their BSPM isochronous maps, before and after implantation of atriobiventricular pacemaker, comparing those with values obtained from a control group of normal individuals [CG], in three situations: (1) native LBBB; (2) RV pacing; and (3) atriobiventricular pacing. RESULTS: Situation (1): mRV and mAS values were similar (41.0±11.8ms x 43.6±13.4ms), with delayed mLV (81.0±12.5ms, p<0.01) and asynchronous with RV and AS areas; situation (2): mRV was greater than in CG (86.8±22.9ms, p<0.001), with greater difference between mAS and mLV (63.4±20.7ms vs. 102.7±20.3ms; p<0,001); situation (3): mLV and mRV were similar (72.0±32.0ms vs. 71.6±32.3ms), mRV was greater than in CG and native LBBB (71.6±32.3ms vs. 35.1±10.9ms and 41.0±11.8ms; p<0.001), and mAS was close to CG and native LBBB values (51.3±32.8ms vs. 50.1±11.4ms and 43.6±13.4ms). CONCLUSION: The body surface potential mapping showed that RV and LV activation times which are similar, and are close to those of the AS area, suggest patterns of synchronized ventricular activation in patients with CHF and LBBB during atriobiventricular pacing.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mapeamento Potencial de Superfície Corporal , Bloqueio de Ramo/fisiopatologia , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/fisiopatologia , Bloqueio de Ramo/terapia , Estudos de Casos e Controles , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Fatores de Tempo , Função Ventricular/fisiologia
20.
Arq. bras. cardiol ; 79(5): 494-499, nov. 2002. tab, graf
Artigo em Português, Inglês | LILACS | ID: lil-325520

RESUMO

OBJECTIVE - To assess the relation between P-wave and QT dispersions in elderly patients with heart failure. METHODS - Forty-seven elderly patients (75.6±6 years) with stable heart failure in NYHA functional classes II or III and with ejection fractions of 37±6 percent underwent body surface mapping to analyze P-wave and QT dispersions. The degree of correlation between P-wave and QT dispersions was assessed, and P-wave dispersion values in patients with QT dispersion greater than and smaller than 100 ms were compared. RESULTS - The mean values of P-wave and QT dispersions were 54±14 ms and 68±27 ms, respectively. The correlation between the 2 variables was R=0.41 (p=0.04). In patients with QT dispersion values > 100 ms, P-wave dispersion was significantly greater than in those with QT dispersion values < 100 ms (58±16 vs 53±12 ms, p=0.04 ). CONCLUSION - Our results suggest that, in elderly patients with heart failure, a correlation between the values of P-wave and QT dispersions exists. These findings may have etiopathogenic, pathophysiologic, prognostic, and therapeutic implications, which should be investigated in other studies


Assuntos
Humanos , Masculino , Feminino , Idoso , Eletrocardiografia , Insuficiência Cardíaca